Malinovskyj, S. and Duka, R. and Polulyah-Chornovol, I. and Sulyma, V. (2026) Biomedical technological features of measuring intraabdominal pressure in complications of diverticulitis. The Eurasia Proceedings of Science, Technology, Engineering and Mathematics (EPSTEM), 41. pp. 222-229. ISSN 2602-3199
|
Text
21-+ICRETS02--.pdf Download (296kB) |
Abstract
Biomedical technologies are used to effectively monitor the condition of patients with acute diverticulitis by measuring intra-abdominal pressure (IAP). Our own data presented in our study indicate the high diagnostic value of IAP monitoring technology as a screening method to prevent the development of complications in the early postoperative period.114 patients with acute diverticulitis were under observation. Patients were divided into two groups. Group I – 56 patients with laparoscopic surgical intervention technology, laparoscopic-assisted technology or using percutaneous drainage with ultrasound navigation technology. Group II – 58 patients with primary surgical intervention during laparotomy.According to our study, the total proportion of patients with complications prevailed in group II – 20 (34.5%) over 6 (10.1%) in group I (p=0.005). Whereas, the use of different surgical methods did not affect the mortality rate in general: 6 (10.3%) in group II and 2 (3.6%) in group I (p=0.2).IAP measurements were performed in patients of groups I and II before surgery and daily in the postoperative period until the urinary catheter was removed. The exception was patients with percutaneous drainage of a purulent focus, in whom a urinary catheter was not installed. According to the consensus of the World Society of the Abdominal Compartment Syndrome (WSACS), normal values of intra-abdominal pressure for a healthy adult are 5–7 mm Hg, while value above 12 mm Hg are considered a sign of intra-abdominal hypertension, which is classified into four stages: stage I: 12–15 mm Hg, stage II: 16–20 mm Hg art., III degree: 21–25 mm Hg. art., IV degree: >25 mm Hg. Art.The purpose of the article is to study, based on biomedical engineering and technological capabilities, the dependence of intraabdominal pressure on the prevalence of the inflammatory process and to identify the influence of the surgical treatment method on intra-abdominal pressure and to determine the prognostic value of intra-abdominal pressure in the diagnosis of the development of abdominal complications in order to prevent their development, reduce mortality and improve treatment outcomes.
| Item Type: | Article |
|---|---|
| Additional Information: | Malinovskyj S., Duka R., Polulyah-Chornovol, I. & Sulyma V. (2026). Biomedical technological features of measuring intraabdominal pressure in complications of diverticulitis. The Eurasia Proceedings of Science, Technology, Engineering and Mathematics (EPSTEM), 41, 222-229.https://doi.org/10.55549/epstem.1519 |
| Uncontrolled Keywords: | Diverticulitis, Intra-abdominal pressure, Measurements; Дивертикуліт, внутрішньочеревний тиск, вимірювання |
| Subjects: | Surgery |
| Divisions: | Departments > Surgery and Urology |
| Depositing User: | Анастасия Жигар |
| Date Deposited: | 15 Nov 2026 03:01 |
| Last Modified: | 15 Nov 2026 03:01 |
| URI: | http://repo.dma.dp.ua/id/eprint/10402 |
Actions (login required)
![]() |
View Item |


